Moxa NPORT 5450AI-M12 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Serwery szeregowe Moxa NPORT 5450AI-M12. Moxa NPort 5450AI-M12-T Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 113
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
NPort 5000AI-M12 Series User Manual
First Edition, June 2012
www.moxa.com/product
© 2012 Moxa Inc. All rights reserved.
Reproduction without permission is prohibited.
Przeglądanie stron 0
1 2 3 4 5 6 ... 112 113

Podsumowanie treści

Strona 1 - First Edition, June 2012

NPort 5000AI-M12 Series User Manual First Edition, June 2012 www.moxa.com/product © 2012 Moxa Inc. All rights reserved. Reproduction without permissi

Strona 2 - Disclaimer

NPort 5000AI-M12 Series Getting Started 2-2 NPort 5150AI-M12 Series Appearance NPort 5250AI-M12 Series Appearance

Strona 3 - Table of Contents

7 7. IP Serial Library The following topics are covered in this chapter:  Overview  IP Serial Library Function Groups  Example Program

Strona 4

NPort 5000AI-M12 Series IP Serial Library 7-2 Overview What is IP Serial Library? IP Serial Library is a Windows library with frequently used serial

Strona 5 - Introduction

NPort 5000AI-M12 Series IP Serial Library 7-3 IP Serial Library Function Groups Server Control Port Control Input/Output Data Port Status Inquiry

Strona 6 - Product Specifications

A A. Pinouts and Cable Wiring The following topics are covered in this appendix:  Pin Assignments and Cable Wiring  Ethernet M12  Power M12 

Strona 7

NPort 5000AI-M12 Series Pinouts and Cable Wiring A-2 Pin Assignments and Cable Wiring Ethernet M12 Housing: shield Power M12 PIN Description 1 In

Strona 8 - Warranty

NPort 5000AI-M12 Series Pinouts and Cable Wiring A-3 Serial Cable Wiring Diagrams Female DB9 to Male DB9

Strona 9 - Getting Started

B B. Well Known Port Numbers In this appendix, which is included for your reference, we provide a list of Well Known port numbers that may cause ne

Strona 10

NPort 5000AI-M12 Series Well Known Port Numbers B-2 UDP Socket Application Service 0 reserved 2 Management Utility 7 Echo 9 Discard 11 Active

Strona 11 - Connecting the Hardware

C C. SNMP Agents with MIB II & RS-232 Like Groups NPort 5000AI-M12 has built-in SNMP (Simple Network Management Protocol) agent software. It su

Strona 12 - DIN-Rail Mounting (optional)

NPort 5000AI-M12 Series SNMP Agents with MIB II & RS-232 Like Groups C-2 IpNetToMediaType IpRoutingDiscards UDP MIB TCP MIB SNMP

Strona 13 - Connecting to the Network

NPort 5000AI-M12 Series Getting Started 2-3 NPort 5450AI-M12 Series Appearance Connecting the Hardware This section describes how to connect NPort

Strona 14 - LED Indicators

NPort 5000AI-M12 Series SNMP Agents with MIB II & RS-232 Like Groups C-3 rs232PortInSpeed rs232PortOutSpeed The Input Signal Table The

Strona 15

D D. Auto IP Report Protocol NPort device servers provide several ways to configure Ethernet IP addresses. One of them is DHCP Client. When you set

Strona 16 - NPort Administration Suite

NPort 5000AI-M12 Series Auto IP Report Protocol D-2 ID List ID Value Description Length Note 1 Server Name Variable ASCII char 2 Hardware ID

Strona 17 - Telnet Console

E E. Compliance Notice CE Warning This is a Class A product. In a domestic environment, this product may cause radio interference in which case th

Strona 18

NPort 5000AI-M12 Series Getting Started 2-4 You should observe the following: • Use separate paths to route wiring for power and devices. If power

Strona 19

NPort 5000AI-M12 Series Getting Started 2-5 STEP 2: Position the NPort 5000AI-M12 on the DIN-Rail, tilting to hook clamps over the top edge of the r

Strona 20 - ATTENTION

NPort 5000AI-M12 Series Getting Started 2-6 Connecting to a Serial Device Connect the serial data cable between NPort 5000AI-M12 and the serial devi

Strona 21

3 3. Initial IP Address Configuration When setting up your NPort 5000AI-M12 for the first time, the first thing you should do is configure the IP ad

Strona 22

NPort 5000AI-M12 Series Initial IP Address Configuration 3-2 Initializing the NPort’s IP Address 1. Determine whether your NPort 5000AI-M12 needs t

Strona 23 - Real COM Mode

NPort 5000AI-M12 Series Initial IP Address Configuration 3-3 Take the following steps to use ARP to configure the IP address: 1. Obtain a valid IP

Strona 24 - TCP Client Mode

NPort 5000AI-M12 Series Initial IP Address Configuration 3-4 4. Type 2 to select Network settings, and then press Enter. 5. Type 1 to select IP a

Strona 25 - Ethernet Modem Mode

NPort 5000AI-M12 Series Initial IP Address Configuration 3-5 7. Press any key to continue… 8. Type m and then press Enter to return to the main m

Strona 26 - Disabled Mode

NPort 5000AI-M12 Series User Manual The software described in this manual is furnished under a license agreement and may be used only in accordance wi

Strona 27 - Web Console Configuration

NPort 5000AI-M12 Series Initial IP Address Configuration 3-6 10. Type y and then press Enter to save the new IP address and restart the NPort 5000A

Strona 28 - Opening Your Browser

NPort 5000AI-M12 Series Initial IP Address Configuration 3-7 7. The NPort 5000AI-M12 will automatically switch from data mode to console mode as i

Strona 29 - Quick Setup

4 4. Choosing the Proper Operation Mode In this chapter, we describe the various NPort 5000AI-M12 operation modes. The options include an operation

Strona 30

NPort 5000AI-M12 Series Choosing the Proper Operation Mode 4-2 Overview NPort 5000AI-M12 Serial Device Servers network-enable traditional RS-232/422

Strona 31

NPort 5000AI-M12 Series Choosing the Proper Operation Mode 4-3 ATTENTION Real COM Mode allows several hosts to have access control over the same NP

Strona 32 - Basic Settings

NPort 5000AI-M12 Series Choosing the Proper Operation Mode 4-4 UDP Mode Compared to TCP communication, UDP is faster and more efficient. In UDP mode

Strona 33 - Network Settings

NPort 5000AI-M12 Series Choosing the Proper Operation Mode 4-5 Reverse Telnet Mode Console management is commonly used by connecting to Console/AUX

Strona 34

5 5. Web Console Configuration The Web Console is the most user-friendly of the methods available to configure the NPort 5000AI-M12. In this chapter

Strona 35 - IP Address Report

NPort 5000AI-M12 Series Web Console Configuration 5-2 Opening Your Browser 1. Make sure your browser has cookies enabled. To enable cookies in Inte

Strona 36 - Serial Settings

NPort 5000AI-M12 Series Web Console Configuration 5-3 4. The NPort 5000AI-M12 homepage will open next. There are two buttons on this page: Quick se

Strona 37 - Serial Parameters

Table of Contents 1. Introduction ...

Strona 38 - Operating Settings

NPort 5000AI-M12 Series Web Console Configuration 5-4 In Step 1/3, you must assign a valid IP address to the NPort 5000AI-M12 before it will work i

Strona 39

NPort 5000AI-M12 Series Web Console Configuration 5-5 In the Step 3/3, you can modify the serial settings. Review your settings at the Finish Set

Strona 40

NPort 5000AI-M12 Series Web Console Configuration 5-6 Export/Import Export/Import allows you to back up and recover your settings. Click Export to

Strona 41

NPort 5000AI-M12 Series Web Console Configuration 5-7 Telnet console Setting Factory Default Necessity Enable or Disable Enable Required ATTEN

Strona 42

NPort 5000AI-M12 Series Web Console Configuration 5-8 IP address Setting Factory Default Necessity E.g., 192.168.1.1 (IP addresses of the form x.x

Strona 43

NPort 5000AI-M12 Series Web Console Configuration 5-9 DNS server 2 configuration items to configure the IP address of the DNS server. DNS Server 2 i

Strona 44

NPort 5000AI-M12 Series Web Console Configuration 5-10 Auto report to TCP port Setting Factory Default Necessity E.g., 4001 4002 Optional Auto r

Strona 45

NPort 5000AI-M12 Series Web Console Configuration 5-11 Port alias Setting Factory Default Necessity 1 to 15 characters (E.g., PLC-No.1) None Opt

Strona 46

NPort 5000AI-M12 Series Web Console Configuration 5-12 Flow control Setting Factory Default Necessity None, RTS/CTS, DTR/DSR, Xon/Xoff RTS/CTS Re

Strona 47

NPort 5000AI-M12 Series Web Console Configuration 5-13 Real COM Mode TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min O

Strona 48

6. Configuring NPort Administrator ... 6-1 Overvi

Strona 49

NPort 5000AI-M12 Series Web Console Configuration 5-14 ATTENTION When “Max connection” is set greater than 1, this means that the NPort 5000AI-M12

Strona 50

NPort 5000AI-M12 Series Web Console Configuration 5-15 Do nothing, Delimiter + 1, Delimiter + 2, Strip Delimiter Do Nothing Optional Delimiter + 1

Strona 51

NPort 5000AI-M12 Series Web Console Configuration 5-16 RFC2217 Mode TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Op

Strona 52 - UDP Multicast

NPort 5000AI-M12 Series Web Console Configuration 5-17 Once the NPort 5000AI-M12 receives both delimiters through its serial port, it immediately pa

Strona 53

NPort 5000AI-M12 Series Web Console Configuration 5-18 TCP Server Mode TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min

Strona 54 - Pair Connection Slave Mode

NPort 5000AI-M12 Series Web Console Configuration 5-19 ATTENTION The Inactivity time should be configured to be larger than the Force transmit time

Strona 55

NPort 5000AI-M12 Series Web Console Configuration 5-20 ATTENTION Delimiter 2 is optional. If left blank, then Delimiter 1 alone trips clearing of t

Strona 56 - S Registers

NPort 5000AI-M12 Series Web Console Configuration 5-21 1 to 65535 966 Optional The Command port is a listen TCP port for IP-Serial Lib commands fr

Strona 57

NPort 5000AI-M12 Series Web Console Configuration 5-22 1-65535 ms: NPort 5000AI-M12 automatically closes the TCP connection if there is no serial da

Strona 58

NPort 5000AI-M12 Series Web Console Configuration 5-23 Delimiter + 1 or Delimiter + 2: The data will be transmitted when an additional byte (for Del

Strona 59 - Accessible IP Settings

1 1. Introduction Welcome to the NPort 5000AI-M12 Series of industrial serial device servers. There are a total of nine models in this series and th

Strona 60 - Auto Warning Settings

NPort 5000AI-M12 Series Web Console Configuration 5-24 Designated Local Port 1/2/3/4 Setting Factory Default Necessity TCP Port No. 5011 (P

Strona 61 - Event Type

NPort 5000AI-M12 Series Web Console Configuration 5-25 UDP Mode Packing length Setting Factory Default Necessity 0 to 1024 0 Optional

Strona 62

NPort 5000AI-M12 Series Web Console Configuration 5-26 Delimiter + 1 or Delimiter + 2: The data will be transmitted when an additional byte (for Del

Strona 63 - Monitor

NPort 5000AI-M12 Series Web Console Configuration 5-27 Management Protocol (IGMP) is used to communicate group membership information between hosts

Strona 64 - Monitor Async-Settings

NPort 5000AI-M12 Series Web Console Configuration 5-28 TCP alive check time Setting Factory Default Necessity 0 to 99 min 7 min Required 0 min:

Strona 65 - Load Factory Default

NPort 5000AI-M12 Series Web Console Configuration 5-29 Ethernet Modem Mode Dial-in The NPort 5000AI-M12 listens for a TCP/IP connection request fro

Strona 66 - Save/Restart

NPort 5000AI-M12 Series Web Console Configuration 5-30 AT Commands The NPort 5000AI-M12 supports the following common AT commands used with a typica

Strona 67

NPort 5000AI-M12 Series Web Console Configuration 5-31 9 S8 Pause time for dial delay (always=2, unit=sec) no action applied 10 S9 Carrier dete

Strona 68

NPort 5000AI-M12 Series Web Console Configuration 5-32 1-65535 ms: The NPort 5000AI-M12 automatically closes the TCP connection if there is no seria

Strona 69

NPort 5000AI-M12 Series Web Console Configuration 5-33 Accessible IP Settings The NPort 5000AI-M12 uses an IP address based filtering method to con

Strona 70 - Configuration

NPort 5000AI-M12 Series Introduction 1-2 Overview NPort 5000AI-M12 device server is designed to make serial devices network-ready in an instant and

Strona 71 - Broadcast Search

NPort 5000AI-M12 Series Web Console Configuration 5-34 Auto Warning Settings Auto warning: Email and SNMP trap Mail Server Mail server Setting Fac

Strona 72 - Unlock Password Protection

NPort 5000AI-M12 Series Web Console Configuration 5-35 ATTENTION Consult your Network Administrator or ISP for the proper mail server settings. The

Strona 73

NPort 5000AI-M12 Series Web Console Configuration 5-36 Authentication failure The user inputs a wrong password from the Console or Administrator. Wh

Strona 74

NPort 5000AI-M12 Series Web Console Configuration 5-37 Trap Setting Factory Default Necessity Enable, Disable Disable Optional This feature help

Strona 75 - Upgrading the Firmware

NPort 5000AI-M12 Series Web Console Configuration 5-38 Monitor Async Click Async under Monitor to show the current status of the serial port. Monit

Strona 76 - Import Configuration

NPort 5000AI-M12 Series Web Console Configuration 5-39 Change Password Input the “Old password” and “New password” to change the password. Leave th

Strona 77

NPort 5000AI-M12 Series Web Console Configuration 5-40 Save/Restart Click Save/Restart will save the current configured settings and restart the NPo

Strona 78

6 6. Configuring NPort Administrator The following topics are covered in this chapter:  Overview  Installing NPort Administrator  Configurati

Strona 79

NPort 5000AI-M12 Series Configuring NPort Administrator 6-2 Overview NPort Administrator lets you install and configure your NPort 5000AI-M12 Series

Strona 80

NPort 5000AI-M12 Series Configuring NPort Administrator 6-3 3. Click Next to install the program using the default program name, or select a differ

Strona 81 - COM Mapping

NPort 5000AI-M12 Series Introduction 1-3 Stop Bits: 1, 1.5, 2 Parity: None, Even, Odd, Space, Mark Flow Control: RTS/CTS and DTR/DSR (RS-232 only),

Strona 82 - On-line COM Mapping

NPort 5000AI-M12 Series Configuring NPort Administrator 6-4 6. Click Next to proceed with the installation. 7. Click Finish to complete the insta

Strona 83

NPort 5000AI-M12 Series Configuring NPort Administrator 6-5 Broadcast Search The Broadcast Search function is used to locate all NPort 5000AI-M12s

Strona 84

NPort 5000AI-M12 Series Configuring NPort Administrator 6-6 3. When the search is complete, the Broadcast Search window will close, and the NPort 5

Strona 85 - Off-line COM Mapping

NPort 5000AI-M12 Series Configuring NPort Administrator 6-7 3. The “Lock” status will change to “Unlock,” and the Administrator utility will keep t

Strona 86 - COM Grouping

NPort 5000AI-M12 Series Configuring NPort Administrator 6-8 2. Unlock the NPort 5000AI-M12 you wish to configure if it is password protected. Right

Strona 87

NPort 5000AI-M12 Series Configuring NPort Administrator 6-9 Upgrading the Firmware Follow these steps to upgrade the firmware of an NPort 5000AI-M12

Strona 88 - Deleting a COM Group

NPort 5000AI-M12 Series Configuring NPort Administrator 6-10 ATTENTION You can simultaneously upgrade the firmware of multiple NPort 5000AI-M12s th

Strona 89

NPort 5000AI-M12 Series Configuring NPort Administrator 6-11 ATTENTION You can simultaneously import the same configuration file into multiple NPor

Strona 90 - Adding a Port to a COM Group

NPort 5000AI-M12 Series Configuring NPort Administrator 6-12 3. The NPort 5000AI-M12 list will appear on the Monitor screen. 4. Right click the p

Strona 91

NPort 5000AI-M12 Series Configuring NPort Administrator 6-13 7. On the Advanced Settings page, select Display warning message for new event and/or

Strona 92

NPort 5000AI-M12 Series Introduction 1-4 MTBF (mean time between failures): NPort 5150AI-M12: 789,341 hrs NPort 5250AI-M12: 639,622 hrs NPort 5450AI

Strona 93 - Modify Ports in a COM Group

NPort 5000AI-M12 Series Configuring NPort Administrator 6-14 10. When one of the NPort 5000AI-M12s loses connection with the Monitor program, a war

Strona 94

NPort 5000AI-M12 Series Configuring NPort Administrator 6-15 Port Monitor The process described here is the same as in the previous “Monitor” sectio

Strona 95 - COM Group

NPort 5000AI-M12 Series Configuring NPort Administrator 6-16 On-line COM Mapping 1. Broadcast Search for NPort 5000AI-M12s on the network. 2. Sel

Strona 96

NPort 5000AI-M12 Series Configuring NPort Administrator 6-17 6. Select the COM Number. COM ports that are “In use” or “Assigned” will also be indic

Strona 97

NPort 5000AI-M12 Series Configuring NPort Administrator 6-18 8. The Serial Parameter settings shown here are the default settings when the NPort 5

Strona 98

NPort 5000AI-M12 Series Configuring NPort Administrator 6-19 10. Select Discard Change to tell Administrator NOT to save the COM Mapping informati

Strona 99

NPort 5000AI-M12 Series Configuring NPort Administrator 6-20 2. Modify the port settings as needed. 3. Right click in the NPort list section and

Strona 100 - IP Serial Library

NPort 5000AI-M12 Series Configuring NPort Administrator 6-21 2. Select a COM number for this COM group. You may select one of the ports already as

Strona 101 - Overview

NPort 5000AI-M12 Series Configuring NPort Administrator 6-22 4. On the COM Grouping page, you can set “Read” and “Write” permissions for every seri

Strona 102 - Example Program

NPort 5000AI-M12 Series Configuring NPort Administrator 6-23 2. Select a COM number for this COM group and check the Auto enumerating COM number f

Strona 103 - Pinouts and Cable Wiring

2 2. Getting Started In this chapter, we give instructions on installing NPort 5000AI-M12 device servers. Software installation is covered in subseq

Strona 104 - Power M12

NPort 5000AI-M12 Series Configuring NPort Administrator 6-24 4. Finally, click Yes to confirm. Adding a Port to a COM Group Follow the steps below

Strona 105 - Serial Cable Wiring Diagrams

NPort 5000AI-M12 Series Configuring NPort Administrator 6-25 3. You will be able to view the serial ports that were assigned to and removed from th

Strona 106 - Well Known Port Numbers

NPort 5000AI-M12 Series Configuring NPort Administrator 6-26 2. Select a COM number that is not in use or assigned to a Group and click OK. 3. Yo

Strona 107

NPort 5000AI-M12 Series Configuring NPort Administrator 6-27 Modify Ports in a COM Group In the following subsections we examine three ways in which

Strona 108

NPort 5000AI-M12 Series Configuring NPort Administrator 6-28 3. Select the Grouping selected port(s) together checkbox and then click OK. 4. You

Strona 109 - RFC1317: RS-232 MIB objects

NPort 5000AI-M12 Series Configuring NPort Administrator 6-29 Changing Advanced Settings and Serial Parameters of the COM Group 1. Check the port sp

Strona 110

NPort 5000AI-M12 Series Configuring NPort Administrator 6-30 3. The Advanced Settings and Serial Parameters pages will be available for modificatio

Strona 111 - Auto IP Report Protocol

NPort 5000AI-M12 Series Configuring NPort Administrator 6-31 Changing the Serial Port Specified as Signal Port for the COM Group 1. Select a serial

Strona 112 - ID List

NPort 5000AI-M12 Series Configuring NPort Administrator 6-32 3. On COM Grouping page, you can specify one serial port whose signals will be taken i

Strona 113 - Compliance Notice

NPort 5000AI-M12 Series Configuring NPort Administrator 6-33 2. Select the IP Address Report, and click the right mouse button to select Settings.

Komentarze do niniejszej Instrukcji

Brak uwag