C320 Turbo/PCI Users Manual
Fourth Edition, July 2008
www.moxa.com/product
© 2008 Moxa Inc., all rights reserved.
Reproduction without permission is prohibited.
Przeglądanie stron 0
1 2 3 4 5 6 ... 100 101

Podsumowanie treści

Strona 1 - C320 Turbo/PCI User’s Manual

C320 Turbo/PCI User’s Manual Fourth Edition, July 2008 www.moxa.com/product © 2008 Moxa Inc., all rights reserved. Reproduction without permission

Strona 2

IntroductionIntellio C320Turbo/PCI User's Manual 1-5❖ Rack mountable-Industrial standard 19” rack❖ Supports most popular OS-Windows NT, Window

Strona 3 - About This Manual

Technical ReferenceIntellio C320Turbo/PCI A-5PCIThe 32-bit Intellio C320Turbo/PCI board complies with PCI Spec. 2.1. Hardwareconfiguration for IRQ an

Strona 4 - Table of Contents

A-6 Intellio C320Turbo/PCI16550C in UART/Basic/Extensive ModulesThe 16550C is an advanced asynchronous controller capable of on-chip hardwareflow con

Strona 5

1-6 Intellio C320Turbo/PCI User's ManualInstallation GuideThis section gives a brief summary of how to install the Intellio C320Turbo/PCIunder e

Strona 6 - 1 Introduction

Intellio C320Turbo/P User's Manual 2-122222222 2 Hardware InstallationHardware InstallationHardware InstallationHardware InstallationThe instal

Strona 7 - Versatile Connection Options

2-2 Intellio C320Turbo/PCI User's ManualStep 6: Replace the system cover.Note ! Each board must occupy one unique IRQ and oneunique memory addre

Strona 8 - Status Indicator

Hardware InstallationIntellio C320Turbo/PCI User's Manual 2-3Without power adapter (for normal condition)In most cases, you need not a power ada

Strona 9 - Features

2-4 Intellio C320Turbo/PCI User's ManualB: Plug the DB25 male end of the shipped 2-meter 10-signal-pin cable(the link cable comes with long ran

Strona 10 - Check List

Hardware InstallationIntellio C320Turbo/PCI User's Manual 2-5Step 8: Connect the first UART Module to the CPU Module. Connect the secondUART Mod

Strona 11 - Installation Guide

2-6 Intellio C320Turbo/PCI User's ManualWithout power adapter (for normal condition)In most cases, you need not a power adapter.Extensive Module

Strona 12 - Hardware Installation

Hardware InstallationIntellio C320Turbo/PCI User's Manual 2-710-singal-pin CablePower AdapterExtensive ModuleBasic ModuleC320 Turbo/PCIC: Plug t

Strona 13

2-8 Intellio C320Turbo/PCI User's ManualTo mount the module(s) on the industrial standard 19” rack, Rack MountKit, including two L-type plates a

Strona 14

C320 Turbo/PCI User’s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with t

Strona 15 - Power Adapter

Hardware InstallationIntellio C320Turbo/PCI User's Manual 2-9If the first test passed, the CPU/Basic Module will then display “Ld” waiting forlo

Strona 16 - CPU Module

2-10 Intellio C320Turbo/PCI User's Manualindicators will light on when local port is opened while DSR and CTS indicators willlight on when remot

Strona 17 - C320 Tur bo/PCI

Intellio C320Turbo/P User's Manual 3-133333333 3 Software Installation In this chapter, software driver installation, configuration and driver

Strona 18 - C320 Turbo/PCI

3-2 Intellio C320Turbo/PCI User's ManualInstalling DriverFollowing is the procedure for installing the Intellio C320Turbo/PCI driver for thefirs

Strona 19 - Operating LED Indicators

Software InstallationIntellio C320Turbo/PCI User's Manual 3-35. Select “MOXA Intellio Family Multiport Board” in the “Select OEM Option”dialog b

Strona 20

3-4 Intellio C320Turbo/PCI User's Manual7. In the “Property” dialog box, click [Port Setting] to enter the “Individual PortSetting” dialog box t

Strona 21 - Mix of Various UART Modules

Software InstallationIntellio C320Turbo/PCI User's Manual 3-5Note ! You may skip the following settings and go directly to the next step 8if you

Strona 22 - 3 Software Installation

3-6 Intellio C320Turbo/PCI User's ManualClassical Mode: It lets MOXA ports behave like generic COM ports.Transmission for small data packets wou

Strona 23 - Installing Driver

Software InstallationIntellio C320Turbo/PCI User's Manual 3-711. Once the system restarts, you may check the event log issued by MOXA drive tose

Strona 24 - Software Installation

3-8 Intellio C320Turbo/PCI User's Manual3. Click on the [Properties...] button to enter the “MOXA Configuration Panel”dialog box.In this configu

Strona 25

About This ManualThis manual is composed of six Chapters and one Appendix. This manual is written for installer, systemadministrator and software prog

Strona 26

Software InstallationIntellio C320Turbo/PCI User's Manual 3-9Adding/Removing BoardFollowing is the procedure to add/remove Intellio C320Turbo/PC

Strona 27

3-10 Intellio C320Turbo/PCI User's ManualWindows 95/98Windows 95/98 supports up to 128 serial ports, from COM1 to COM128. To fullyintegrate the

Strona 28 - Configuring Board and Port

Software InstallationIntellio C320Turbo/PCI User's Manual 3-11See chapter, “HardwareInstallation”YesDriver installed before?NoInstall the Intell

Strona 29

3-12 Intellio C320Turbo/PCI User's ManualFirst Time Driver Installation StageThe stage presents the steps for installing the driver for the firs

Strona 30 - Removing Driver

Software InstallationIntellio C320Turbo/PCI User's Manual 3-133.Type “A:\Windows.95” in the Location field,and click [OK]. The system will star

Strona 31

3-14 Intellio C320Turbo/PCI User's Manual6. Click [Next>].7. Click [Next>].

Strona 32

Software InstallationIntellio C320Turbo/PCI User's Manual 3-15Port Configuration StageThis stage displays the “C320Turbo/PCI Installation” dialo

Strona 33

3-16 Intellio C320Turbo/PCI User's ManualIn addition, in the “C320Turbo/PCI Installation” dialog box, you may click on[Advanced Settings] button

Strona 34

Software InstallationIntellio C320Turbo/PCI User's Manual 3-17Board and Port Ready StageClick [OK] for all the dialog boxes to finish the config

Strona 35 - 7. Click [Next>]

3-18 Intellio C320Turbo/PCI User's ManualPComm utility Terminal emulator (See “Serial Programming Tools”) orHyperTerminal to transmit/receive da

Strona 36 - Port Configuration Stage

Table of ContentsIntroductionIntroductionIntroductionIntroduction ...

Strona 37

Software InstallationIntellio C320Turbo/PCI User's Manual 3-19Configuring Board and PortIf you already have installed the driver and want to re-

Strona 38 - Board and Port Ready Stage

3-20 Intellio C320Turbo/PCI User's Manual3. In the “Property” dialog, you may click on the [Port Setting] button to enter the“Individual Port Se

Strona 39

Software InstallationIntellio C320Turbo/PCI User's Manual 3-21 In the “Advanced Settings” dialog box, you may customize the dr

Strona 40

3-22 Intellio C320Turbo/PCI User's Manual4. Click [OK] in the “Individual Port Setting” and the “Property” dialog boxes togo back to the “MOXA C

Strona 41

Software InstallationIntellio C320Turbo/PCI User's Manual 3-23Updating driverOpen the [Control Panel] and click on the [System] button, and sele

Strona 42

3-24 Intellio C320Turbo/PCI User's ManualUNIXInstalling DriverUp to four boards of combination of Intellio C320Turbo/PCI and C320Turbo canbe ins

Strona 43

Software InstallationIntellio C320Turbo/PCI User's Manual 3-251. /dev/fd0135ds18 (A: 1.44MB)2. /dev/fd096ds15 (A: 1.2 MB)3. /dev/fd1135ds18 (B:

Strona 44 - Removing driver

3-26 Intellio C320Turbo/PCI User's Manual☞ Now you can run any ready-made applications such as getty terminalor PPP/SLIP. You can also start to

Strona 45

Software InstallationIntellio C320Turbo/PCI User's Manual 3-27MOXA TTY Device Naming ConventionIf the Intellio C320Turbo/PCI is successfully con

Strona 46

3-28 Intellio C320Turbo/PCI User's ManualTaking 8 port Intellio C320Turbo/PCI as an example,Administration Utility - mxadmYou can use the admini

Strona 47

Serial Programming ToolsSerial Programming ToolsSerial Programming ToolsSerial Programming Tools...

Strona 48

Software InstallationIntellio C320Turbo/PCI User's Manual 3-29“Board type” field to select board type, C320Turbo/PCI. And a list of IntellioC320

Strona 49 - To Control Board

3-30 Intellio C320Turbo/PCI User's Manualfile /etc/inittab which could also be manually modified by system administrator. Its value comes from

Strona 50

Software InstallationIntellio C320Turbo/PCI User's Manual 3-31Baud Rate MappingThis advanced feature is set to “High Band” by default, indicatin

Strona 51 - Advanced Configuration

3-32 Intellio C320Turbo/PCI User's Manualexcept flow control, thus non-terminal applications such as data acquisition willbenefit from it, e.g.

Strona 52

Software InstallationIntellio C320Turbo/PCI User's Manual 3-33Board ResetThe board reset utility eliminates the need to shut down the UNIX syste

Strona 53 - Performance Tuning

3-34 Intellio C320Turbo/PCI User's ManualChecking Board Initialization StatusWhen the system starts up and enters into the multiuser mode, you s

Strona 54 - Driver Removal

Intellio C320Turbo/PCI User's Manual 4-144444444 4 Serial Programming ToolsSerial Programming ToolsSerial Programming ToolsSerial Programming T

Strona 55

4-2 Intellio C320Turbo/PCI User's ManualPComm Programming LibraryThe serial communication library is to assist you to develop programs for seria

Strona 56 - Serial Programming Tools

Serial Programming ToolsIntellio C320Turbo/PCI User's Manual 4-3Monitor (for MOXA boards under Windows NT Only)A useful port status monitoring p

Strona 57 - Utilities

4-4 Intellio C320Turbo/PCI User's ManualTerminal EmulatorThe Terminal Emulator features multi-windows and supports terminal types ofVT100 and AN

Strona 58

Intellio C320Turbo/P User's Manual 1-111111111 1 IntroductionThis manual covers both the hardware and software installation and configuration o

Strona 59 - Terminal Emulator

Serial Programming ToolsIntellio C320Turbo/PCI User's Manual 4-5UNIXProgramming the MOXA PortsThe system calls that apply to standard tty port a

Strona 60 - Programming the MOXA Ports

4-6 Intellio C320Turbo/PCI User's ManualSyntax for UNIX SVR4#include <sys/stropts.h>#include <sys/sysmacros.h>#define MIBUFED 0x401s

Strona 61 - 2. MOBUFED

Serial Programming ToolsIntellio C320Turbo/PCI User's Manual 4-73. MTCRTSThis function, only valid when hardware flow control is turned off (see

Strona 62 - 3. MTCRTS

4-8 Intellio C320Turbo/PCI User's ManualSyntax for UNIX SVR4#include <sys/stropts.h>#include <sys/sysmacros.h>#define MTCDTR 0x404#d

Strona 63 - 5. MLOWATER

Serial Programming ToolsIntellio C320Turbo/PCI User's Manual 4-9Syntax for SCO UNIX/XENIX#define MLOWATER 0x405int lowater; /* low water value

Strona 64 - 6. MSTATUS

4-10 Intellio C320Turbo/PCI User's Manual7. MHWFLOWThis function is used to enable/disable hardware flow control. The first open()function of a

Strona 65 - 7. MHWFLOW

Serial Programming ToolsIntellio C320Turbo/PCI User's Manual 4-11UtilitiesYou can use the administration utility, mxadm, to monitor port activit

Strona 66

4-12 Intellio C320Turbo/PCI User's ManualPress Enter on the port, that the cursor stays, to view the port’s communicationparameters, signal stat

Strona 67

Serial Programming ToolsIntellio C320Turbo/PCI User's Manual 4-131. Select and Press Enter on item “Communication Setup” to setup up all thecom

Strona 68

4-14 Intellio C320Turbo/PCI User's Manual

Strona 69

1-2 Intellio C320Turbo/PCI User's ManualLow Host Processor OverheadThe Intellio C320Turbo/PCI is equipped with two high performance processors(T

Strona 70

Intellio C320Turbo/PCI User's Manual 5-155555555 5 Connection Option and Cable WiringConnection Option and Cable WiringConnection Option and Cab

Strona 71 - Straight-through Cable

5-2 Intellio C320Turbo/PCI User's ManualUART Module C32045T/71TDB25 Female Connector2RxD3TxD4CTS5RTS6DTR7GND8DCD20 DSRUART Module C32047TDB25 Ma

Strona 72 - C32047T DTE Device

Connection Option and Cable WiringIntellio C320Turbo/PCI User's Manual 5-3PC COM2 port, Serial Printer,Terminal, or any DTE DeviceC32047TNull Mo

Strona 73 - C32071T DCE Device

5-4 Intellio C320Turbo/PCI User's ManualType 2: Connecting UART Module to a DCE device.Modem,or any DCE DeviceC32045T/71TNull Modem CableC32045T

Strona 74

Connection Option and Cable WiringIntellio C320Turbo/PCI User's Manual 5-5Type 3: Connecting UART Module to a DTE device with 3-pin wiring.If t

Strona 75

5-6 Intellio C320Turbo/PCI User's ManualPC COM2 port, Serial Printer,Terminal, or any DTE DeviceC32047TC32047T DTE DeviceDB25 Male Cable Wiring

Strona 76

Connection Option and Cable WiringIntellio C320Turbo/PCI User's Manual 5-7RS-422 Cable Wiring for C32061T/C32065TThe following RS-422 UART Modul

Strona 77

5-8 Intellio C320Turbo/PCI User's ManualThe followings are operation modes for RS-422:RS-422 Point-to-point RS-422 BroadcastingC32061T/65T RS-42

Strona 78 - RS-422 Impedance Matching

Connection Option and Cable WiringIntellio C320Turbo/PCI User's Manual 5-9RS-422 Impedance MatchingWhen an electrical signal travels through two

Strona 79 - RJ45 JACK

5-10 Intellio C320Turbo/PCI User's ManualRS-232 Cable Wiring for C32080T/81T/82T/83T & CN20040For Basic/Extensive Modules, only RS-232 inter

Strona 80 - RJ45 Plug Pin 1

IntroductionIntellio C320Turbo/PCI User's Manual 1-32345678123456781Extensive ModuleBasic Module UARTModuleCPUModuleUARTModuleC320 Turbo/PCIDB25

Strona 81 - Cable CN20040

Connection Option and Cable WiringIntellio C320Turbo/PCI User's Manual 5-11Type 1: Connecting Basic/Extensive Module to a DTE device.PC COM2 por

Strona 82

5-12 Intellio C320Turbo/PCI User's ManualType 2: Connecting Basic/Extensive Module to a DCE device.Modem,or any DCE DeviceC3208xTCable CN20040RJ

Strona 83 - C32020T Link Cable

Connection Option and Cable WiringIntellio C320Turbo/PCI User's Manual 5-13Type 3: Connecting Basic/Extensive Module to a DTE device with 3-pinw

Strona 84

5-14 Intellio C320Turbo/PCI User's ManualC32020T Link CableThere are two different types of link cables: 25-signal-pin link cable and 10-signal-

Strona 85

Connection Option and Cable WiringIntellio C320Turbo/PCI User's Manual 5-1510-signal-pin Link Cable (for long range extension only)If the extern

Strona 86 - Troubleshooting

5-16 Intellio C320Turbo/PCI User's Manual

Strona 87

Intellio C320Turbo/PCI User's Manual 6-166666666 6 TroubleshootingTroubleshootingTroubleshootingTroubleshootingGeneral TroubleshootingCommon In

Strona 88

6-2 Intellio C320Turbo/PCI User's Manualor box or board to verify. In addition, PComm utility “Diagnostic” forWindows NT and Windows 95/98 is go

Strona 89

TroubleshootingIntellio C320Turbo/PCI User's Manual 6-34. Error messages appear on CPU/Basic Module LED display.Any of the following messages me

Strona 90 - Windows NT

6-4 Intellio C320Turbo/PCI User's Manual5. Upon system startup or driver initialization, the “Number of portsmismatch” message appears.Hardware

Strona 91

1-4 Intellio C320Turbo/PCI User's ManualPowerful Serial Comm Developing ToolsFor application development, MOXA provides the easy-to-use while po

Strona 92 - Windows 95/98

TroubleshootingIntellio C320Turbo/PCI User's Manual 6-5Windows NTThis section is specific for troubleshooting under Windows NT. For generalprobl

Strona 93

6-6 Intellio C320Turbo/PCI User's Manual5. After system starts, error message “MOXA C320Turbo Multiport Board #1addr(XXX): CPU/Basic module down

Strona 94

TroubleshootingIntellio C320Turbo/PCI User's Manual 6-7Windows 95/98 This section is specific for troubleshooting under Windows 95/98. For gene

Strona 95

6-8 Intellio C320Turbo/PCI User's Manual6. Error message “C320Turbo/PCI (BusNo=xx, DevNo=xx) at base memory[XXX] interrupt failure!” appears. T

Strona 96 - Technical Reference

TroubleshootingIntellio C320Turbo/PCI User's Manual 6-94. When respawning quite a few number of tty ports, the following errormessages appear: “

Strona 97 - CPU Module Front View

6-10 Intellio C320Turbo/PCI User's Manual

Strona 98

Intellio C320Turbo/PCI A-1AAAAAAAAppppppppppppppppeeeeeeeennnnnnnnddddddddiiiiiiiixxxxxxxxAAAA Technical ReferenceTechnical ReferenceTechnical Refere

Strona 99 - A-4 Intellio C320Turbo/PCI

A-2 Intellio C320Turbo/PCI CPU Module and UART Module for Desktop Option CPU Module (for Desktop option) 40 MHz TMS320C52 processor 16 KB ROM and

Strona 100 - Dual-Ported RAM

Technical ReferenceIntellio C320Turbo/PCI A-3 Basic Module and Extensive Module for Rackmount Option Basic Module (for Rackmount option)

Strona 101 - A-6 Intellio C320Turbo/PCI

A-4 Intellio C320Turbo/PCIBasic Module ( Front View ) Multiport ControllerB?a?s?i?c M?o?d?u?l?ePower TxD RxD DTR DSR RTS CTS DCD Module Cha