AWK-5222 User’s Manual Other Console Configurations
3-40
Admin auth type (for V1, V2c, V3, and V3 only)
Setting Description Factory Default
No Auth Use admin account to access objects. No
authentication
MD5 Provide authentication based on the
HMAC-MD5 algorithms. 8-character
passwords are the minimum requirement
for authentication.
SHA Provides authentication based on
HMAC-SHA algorithms. 8-character
passwords are the minimum requirement
for authentication.
No Auth
Admin private key (for V1, V2c, V3, and V3 only)
Setting Description Factory Default
Disable No data encryption
DES DES-based data encryption
AES AES-based data encryption
Disable
Private Key
A data encryption key is the minimum requirement for data encryption (maximum of 63
characters)
Private MIB Information Device Object ID
Also know as OID. This is the AWK-5222’s enterprise value. It is fixed.
Storm Protection
In general, one host should not be allowed to occupy unlimited bandwidth, particularly when the
device malfunctions. For example, so-called “broadcast storms” could be caused by an incorrectly
configured topology or a malfunctioning device.
Storm Protection
Setting Description Factory Default
Enable/Disable Enable or disable Broadcast Storm
Protection globally for multicast packets
Enable
Multicast and flooding
Setting Description Factory Default
Enable/Disable If you enable Storm Protection, the
Multicast and flooding option will show
up. You can Enable or Disable Broadcast
Storm Protection globally for unknown
multicast and unknown unicast packets.
Disable