Moxa M-1401 Instrukcja Obsługi Strona 78

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 129
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 77
ioLogik MXIO DLL API Reference Direct I/O Command Sets
6-41
Pulse2K_SetSafeValues
This function code is used to set the safe value.
C/C++
Arguments
Return Value
int Pulse2K_SetSafeValues ( int hConnection,
BYTE bytStartChannel,
BYTE bytCount,
DWORD dwValue);
hConnection: The handle for an I/O connection.
bytStartChannel: Specifies the starting channel.
bytCount: The number of channels to set.
dwValue: Stores the safe value, each bit holds the value
of one channel. A bit value of 0 represents the
safe value of the start channel. A bit value of 1
represents the value of the second pulse
channel. The values are:
0: stop
1: start
Succeed MXIO_OK.
Fail Refer to Return Codes.
Pulse2K_GetSafeValue
This function code is used to get the safe value for a specific pulse
channel.
C/C++
Arguments
Return Value
int Pulse2K_GetSafeValue( int hConnection,
BYTE bytChannel,
BYTE * bytValue);
hConnection: The handle for an I/O server connection.
bytChannel: The desired channel.
bytValue: A pointer to the specific pulse channel’s
power on value. The values are:
0: stop
1: start
Succeed MXIO_OK.
Fail Refer
t
oRe
t
u
r
nCodes.
Przeglądanie stron 77
1 2 ... 73 74 75 76 77 78 79 80 81 82 83 ... 128 129

Komentarze do niniejszej Instrukcji

Brak uwag